{"id":2497,"date":"2018-01-30T05:54:43","date_gmt":"2018-01-30T11:54:43","guid":{"rendered":"http:\/\/flow-proen.wcanvas.website\/?page_id=2497"},"modified":"2021-11-18T16:17:13","modified_gmt":"2021-11-18T22:17:13","slug":"aeroenfriadores-tubos-alentados","status":"publish","type":"page","link":"https:\/\/flowproen.com\/en\/productos\/intercambiadores-de-calor\/aeroenfriadores-tubos-alentados\/","title":{"rendered":"Air cooled heat exchangers | Air cooled condensers"},"content":{"rendered":"<p>[vc_row][vc_column][vc_custom_heading text=&#8221;Air Cooled heat exchangers&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_column_text]<span style=\"font-weight: 400;\">Air Cooled Heat Exchangers are used mainly in refineries in oil processing and in the processing and transportation of natural gas where the worldwide accepted API (American Petroleum Institute) standard intended for the special requirements of such demanding operations was developed many years ago, according to which almost all clients order such air-cooled heat exchangers. In technical jargon, these heat exchangers are indicated as API-exchangers. They are distinguished by their use at high operating temperatures and pressures, with highly corrosive and flammable media requiring special structures, materials and demanding welding procedures (plug chambers with extraordinary sheet metal thicknesses, duplex steels, etc.). In other industries, the conditions are not so demanding and the technical design of heat exchangers is resolved according to traditions in such industries, according to the specific requirements of customers or our experience, naturally considering the applicable standards for the construction of such pressure facilities.<\/span>[\/vc_column_text][vc_gallery type=&#8221;image_grid&#8221; images=&#8221;3009,3010&#8243; css=&#8221;.vc_custom_1519332962234{border-radius: 5px !important;}&#8221;][vc_gallery type=&#8221;image_grid&#8221; images=&#8221;3011,3012&#8243; css=&#8221;.vc_custom_1519332969062{border-radius: 5px !important;}&#8221;][vc_gallery type=&#8221;image_grid&#8221; images=&#8221;3015,3013&#8243; css=&#8221;.vc_custom_1519332977099{border-radius: 5px !important;}&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_accordion active_section=&#8221;1&#8243; collapsible_all=&#8221;true&#8221;][vc_tta_section title=&#8221;Technical parameters and important details&#8221; tab_id=&#8221;1517325489614-32d147c5-9837624a-631c&#8221;][vc_column_text]<\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Tube length up to 18 m (longer is possible with special arrangements)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Tube diameter: 19.05 \u00f7 50.8 mm<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Delivery in the preassembled condition upon request<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Design for corrosive fluids possible (Wet sour service, Lethal Service)<\/span><\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Materials for pressure parts&#8221; tab_id=&#8221;1517325489641-9278886a-c043624a-631c&#8221;][vc_column_text]<\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Carbon Steel<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Stainless Steel<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Duplex Steel<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Special Alloys (mainly used 825 and 625)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Copper<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Brass<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Titanium<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Weld-Overlay (cladding) of internal space of headers combining carbon steel and high alloyed materials<\/span><\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Design of fan units&#8221; tab_id=&#8221;1517325869536-24116215-0b3d624a-631c&#8221;][vc_column_text]<\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Direct Drive<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Belt Transmission and Gear Box<\/span><\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Design of Air Cooled Coolers&#8221; tab_id=&#8221;1517331289582-331a3622-3ca4624a-631c&#8221;][vc_column_text]<\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">HTRI (ASPEN+) \/ HTFS thermal calculations<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">API 661<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">ASME<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">EN<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">TR-CU<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">ATEX (94\/9\/EC)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Upon request, CFD possible (ANSYS Fluent)<\/span><\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Possible Components&#8221; tab_id=&#8221;1519229043431-50386030-882f&#8221;][vc_column_text]<\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Cladding<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Fan Units<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Finned Tubes<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">I &amp; C<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Louvres<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Pre-Assembly<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Run-Test<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Steam Coil<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Steel Structure<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Tube Bundle<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Recirculation (winterization)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Other Spare Parts<\/span><\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][\/vc_tta_accordion][vc_separator css=&#8221;.vc_custom_1517332849782{padding-top: 20px !important;padding-bottom: 20px !important;}&#8221;]<div class='logos-wrapper style-1'><ul class='clients clients-col-3' ><\/ul><\/div>[\/vc_column][\/vc_row][vc_row][vc_column][vc_custom_heading text=&#8221;Air Cooled condensers&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_column_text]<span style=\"font-weight: 400;\">Electricity production processes result in emissions of low-potential heat into the atmosphere. Air-cooled Condensers (Heat Exchangers) use corrosion-free media at low pressures (water steam, water and glycol mixtures). In many cases cooling of extreme thermal powers is needed. This includes cooling of gas and diesel engines, gas and steam turbines and condensation of the emission steam of steam turbines. More and more, air-cooling replaces water-cooling in power engineering, where it is used a standard as water is rarer in some industrial areas and more expensive. In many areas which require the production of electricity, water sources are lacking and in concentrated industrial areas where water is available, its price is very high.<\/span>[\/vc_column_text][vc_gallery type=&#8221;image_grid&#8221; images=&#8221;3018,3019&#8243;][vc_gallery type=&#8221;image_grid&#8221; images=&#8221;3020,3021&#8243;][vc_gallery type=&#8221;image_grid&#8221; images=&#8221;3023,3022&#8243;][vc_separator color=&#8221;white&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_accordion active_section=&#8221;1&#8243; collapsible_all=&#8221;true&#8221;][vc_tta_section title=&#8221;Typical scope of supply, including accessories&#8221; tab_id=&#8221;1517325489614-32d147c5-98378f5d-d8ae&#8221;][vc_column_text]<\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">ACC (tube bundles and steel structure)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Air evacuation system (Steam jet ejectors, water ring vacuum pumps)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Condensate tank<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Condensate pumps<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Steam duct between TG and ACC<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Internal piping, including valves<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Electric supply (switchgears, cables, etc.)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">I &amp; C system<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Assembly on Site, commissioning<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Documentation<\/span><\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Possible Components&#8221; tab_id=&#8221;1517325489641-9278886a-c0438f5d-d8ae&#8221;][vc_column_text]<\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Cladding<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Fan Units<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Finned Tubes<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">I &amp; C<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Louvres<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Pre-Assembly<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Run-Test<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Steam Coil<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Steel Structure<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Tube Bundle<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Recirculation (winterization)<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Other Spare Parts<\/span><\/li>\n<li style=\"font-weight: 400;\"><\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][\/vc_tta_accordion][vc_separator css=&#8221;.vc_custom_1517332849782{padding-top: 20px !important;padding-bottom: 20px !important;}&#8221;][vc_custom_heading text=&#8221;Brand&#8221; use_theme_fonts=&#8221;yes&#8221; css=&#8221;.vc_custom_1520448620924{padding-bottom: 20px !important;}&#8221;]<div class='logos-wrapper style-1'><ul class='clients clients-col-3' ><li class='client'><a href='http:\/\/www.bronswerk.cz\/en\/' target='_blank'><img src='https:\/\/flowproen.com\/wp-content\/uploads\/2018\/02\/Bronswerk-01.jpg' alt=''><\/a><\/li><\/ul><\/div>[\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_custom_heading text=&#8221;Air Cooled heat exchangers&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_column_text]Air Cooled Heat Exchangers are used mainly in refineries in oil processing and in the processing and transportation of natural gas where the worldwide accepted API (American Petroleum Institute) standard intended for the special requirements &hellip;<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":2245,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-2497","page","type-page","status-publish","hentry"],"translation":{"provider":"WPGlobus","version":"2.12.2","language":"en","enabled_languages":["es","en"],"languages":{"es":{"title":true,"content":true,"excerpt":false},"en":{"title":true,"content":true,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/flowproen.com\/en\/wp-json\/wp\/v2\/pages\/2497"}],"collection":[{"href":"https:\/\/flowproen.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/flowproen.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/flowproen.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/flowproen.com\/en\/wp-json\/wp\/v2\/comments?post=2497"}],"version-history":[{"count":33,"href":"https:\/\/flowproen.com\/en\/wp-json\/wp\/v2\/pages\/2497\/revisions"}],"predecessor-version":[{"id":4418,"href":"https:\/\/flowproen.com\/en\/wp-json\/wp\/v2\/pages\/2497\/revisions\/4418"}],"up":[{"embeddable":true,"href":"https:\/\/flowproen.com\/en\/wp-json\/wp\/v2\/pages\/2245"}],"wp:attachment":[{"href":"https:\/\/flowproen.com\/en\/wp-json\/wp\/v2\/media?parent=2497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}